| SAFA Symposium 9 May 2019, Sensear Headsets & MTL831C Multiplexer Transmitter
| |
| Dear customers, This month we will focus on the SAFA Symposium which will take place on the 9th of May. Extech will be distributing Sensear in Africa and Eaton have release the New MTL831C Multiplexer Transmitter Extech Safety Systems are the sole agents for MTL, Beka Associates, Extronics, MercuryHMI, and authorised reseller for Aegex (Zone 1 tablets), i.safe mobile (smart phone & tablet) CorDEX (Digitherm Camera), Sensear (Headsets) & Xplore Technologies in Southern Africa.
| |
|
SAFA Symposium 9 May 2019
The South African Flameproof Association (SAFA) is excited to announce that the 2019 annual symposium will be held on Thursday, 9 May 2019 at Carnival City Casino in Brakpan.
The theme of the symposium is ‘Ex IN ACTION’ and the aim is to share knowledge and information on explosion prevention. We invite persons and organisations that wish to present papers to submit a short synopsis for consideration.
Extech will be exhibiting at the symposium.
| |
| Sensear Hazardous Area certified Intrinsically Safe Bluetooth headsets Extech has agreed to distribute Sensear products in Africa. Sensear offer Hazardous Area certified Intrinsically Safe Bluetooth headsets to complement the range of Ex smart phones & tablets.
Sensear is a global leader in developing and manufacturing best-in-class digital Communication and Active Listening Headsets and Earplugs for use in high noise and hazardous environments.
Sensear's patented SENSTM technology simultaneously enhances speech, and suppresses background noise so that users can verbally communicate, protect their hearing, and still maintain 360-degree awareness of their surroundings in noisy environments such as oil & gas, mining, construction, heavy manufacturing and other industrial workplaces.
https://www.sensear.com/communication-headsets-product-range
| |
| Eaton’s MTL830C range multiplexers adds RoHS compliance and improved form factor Power management company, Eaton has released updated versions of its MTL830 range multiplexers for Zone 0 hazardous area temperature measurement applications, improving the form factor to minimise hand wiring and simplify installation and maintenance, as well as making them RoHS compliant. The MTL830 range of multiplexers avoids the need to isolate each instrument loop, reducing the cost of installed wiring by up to 50% by communicating the input of multiple hazardous-area temperature sensors over a single twisted pair data highway. Further savings are achieved by reducing the number of inputs to the control system, cabinet space and weight.
MTL831C multiplexer transmitters are normally sited in the hazardous area, typically mounted close to field instruments in an IP65-rated enclosure, supporting thermocouple, RTD and mV analogue sensor inputs. Compatible safe-area MTL838C receivers translate the information transmitted from the MTL831C via the data highway and provide serial Honeywell LLMUX or Modbus outputs, with status information, to feed to host PLC, PC or DCS controllers. The single data highway cable, a simple twisted pair or pair of wires within an IS (intrinsically safe) multi-core cable, supports communication between the safe and hazardous areas over distances up to 1km, and also provides power to the transmitters – no additional field power is required. If the multiplexer transmitter is located in the hazardous area, the data highway must be protected by an MTL5053 IS digital isolator.
“An important component in hazardous area temperature measurement applications, our MTL830 range multiplexers reduce installation time and costs for intrinsically safe hazardous-area cabling” said Niaz Ahmed, Associate Product Line Manager, Eaton. “We have invested in the development of the MTL830C multiplexer range to support our large installed base of temperature multiplexers worldwide. This allows migration of MTL830B installations to MTL831C and MTL838C products whilst retaining the same sensors, cabling and control system interface ”
By using two transmitters and one receiver, the multiplexer system can communicate the status of up to 32 inputs, reducing the number of hazardous area wiring pairs from 32 to one. This saves installation time and further reduces costs by eliminating long runs of expensive thermocouple compensation cable from the hazardous to the safe area. Also, if 3- or 4-wire RTDs are used, costs are reduced by terminating each RTD at the transmitter or its enclosure, without the need for additional wiring or components.
| |
| As sole agents for MTL, Beka Associates, Extronics, MercuryHMI and authorised reseller for AEGEx, i.safe Mobile, CorDEX, Sensear & XPlore Technologies in Southern Africa, below are some of the areas that Extech Safety Systems can assist with: • Intrinsically Safe Zener Barriers and Galvanic Isolators • HART Interfaces • Fieldbus • Industrial Ethernet • Industrial Security • Industrial Wireless Networks • Visualisation • Displays, Indicators, Sounders, Beacons and Lamps • Intrinsically Safe & Flameproof Cameras (incl. Infra Red) • Rugged IS Smartphones & tablets (Android & Windows) • Hazardous area Access Points for zone 1 (AP of your choice) • Hazardous Area CCTV camera for Group I & II
• Hazardous Area Barcode scanners (Bluetooth)
• Wi-fi/RFID Tracking (incl. Extronics Advance; Aeroscout Industrial)
• Surge Protection
• Process Alarm Equipment
• Hazardous Area Access Control Systems
If you require anything further, please send us an email or give us a call. We will be happy to assist!
Visit the Extech Website or follow us on Facebook or LinkedIn
| |
|
|
|
|